PROBLEM |
CAUSE |
SOLUTION |
Salt crystals form overnight. May clog lines or VUE aspirator. |
Too much salt in oxidizer. solution Copper level too high. |
Add water to etch machine. Add less salt to next batch of solution. |
Low reading on meters, may ring low set alarm. |
Copper content to high. |
Add water or salt water to etch. |
|
Filters in oxidizer or acid pickup tubes clogged. |
Clean filters. |
|
Aspirator plugged with salt or foreign material. |
Back flush lines with water to clear. |
|
Etching too fast for VUE to keep up. |
Allow more space between panels being etched on conveyor. |
VUE unable to regenerate fast enough to keep up with etching at all or most times. |
Aspirator capacity too low. |
Contact Oxford V.U.E., Inc. for aspirator or Chemical Section upgrade. |
Meters too sensitive, may ring high set alarm. |
Copper content too low. |
Add sodium chlorate powder as required until normal copper content is reached SEE TEXT. Use titration to determine copper level. |
|
Etch temperature too low. |
Raise etch temp. to 125°F (52°C). |
System does not come on or goes on and off while regenerating and releasing spent etchant. |
Filter in etch line dirty. Final filter clogged or salt crystals in the line. |
Clean Filters. |
|
Flow valve improperly set. |
Readjust flow valve to 20 - 25 PSI. |
|
Etch machine pressure low. |
Check etch machine pressure at VUE-20 - 25 lbs required. |
Etching speed slow. |
Temperature low. Copper content (and salt) low. |
Adjust to normal. Check copper content. |
|
Rinse water diluting etch. |
Minimize any water drag-in to etch. |
Regeneration slow. |
Filters in oxidizer and/or acid barrel pickup tubes clogged. |
Clean pickup tubes and lines. |
|
Etch machine pressure low, causing slow aspiration. |
Clean filters. |
Rapid movements, fluctuations of meters, or insensitivity. |
Air bubbles in etch. |
See Manual. |
Etch moving backwards, e.g., from etch machine to barrels. |
Blockage in return line from VUE. |
Clear constriction or blockage. Check level of salt in etcher. Make sure there are no valves in return line. |
|
Too much salt in etcher. |
Verify oxidizer concentration by weighing chemicals first. If correct, reduce salt in next batch. |
|
Leaky valve. |
Replace valve. |